Computer Room Fire Solution
View service
COMPUTER ROOM FIRE SOLUTION
Basic Requirements for Fire Extinguishing Solutions
Because computer equipment is precision instruments, sensitive electronic and data equipment, while preventing fires, we need to pay attention to the following items:
§ Fire extinguishing solution should not cause damage to electronic equipment.
§ It is best to have no residue in the extinguishing solution and be non-corrosive.
§ Require reliable quality and performance of the alarm system in the computer room.
§ Adequate design of fire extinguishing agents to ensure sufficient fire extinguishing time.
From the above system requirements, it can be concluded that using the HAFEX Hybrid S-Type aerosol fire extinguishing system and supporting alarm system is the best solution.
HAFEX Hybrid is a new type of aerosol fire extinguishing technology (Third Generation). It absorbs the advantage of traditional aerosol technology of K-Type (Potassium nitrate) and adds organic substance carbon, hydrogen, and oxygen to the agent, reduction reaction and enter the fire field with the Newest and the cleanest Aerosol fire extinguishing agent.
HAFEX Hybrid S-Type technology uses the adhesive properties of polymer polymers to wrap the Potassium ions, Strontium ions (S-Type) and their compounds after the aerosol fire extinguishing agent is deployed with flocculent sediments, so that the generated solid particles will be automatically absorbed. The charge particles ensure that the surface is not saturated, and the tension is compensated to reach a stable state. The S-Type technology truly solves the problem of electrical current conductivity and corrosiveness caused by K-Type aerosol fire extinguishing agents. The S-Type will not cause secondary damage to sensitive electronic equipment guaranteed.
Design methods for fire extinguishing systems:
§ 1. Measure the area and determine the size, length, width, and height of the room equals cubic meter (M³).
§ 2. Based on the space size of the computer room, calculate the dosage of aerosol fire extinguishing agent using a calculation formula.
§ Select the correct aerosol model and determine the quantity.
§ Calculate the number of smoke and temperature sensors, as well as the installation location of the Fire control panel, based on the size of the room.
§ Mini HAFEX aerosol fire extinguishers need to be installed separately for computer hosts, distribution cabinets, etc. in the computer room, and the model depends on the size of the space.
Typical design solution:
Price Available on Request